Backflow prevention and testing

Backflow means water running backwards, out of your plumbing back into the public supply. It can happen when pressure in the main drops. Backflow preventers stop it, and some must be tested every year.

  • Shut-offs that actually close
  • Quarter-turn ball valves fitted
  • Pressure checked at the meter
  • Every joint watched under pressure
A red fire hydrant in a rainy parking lot

The city supply, kept clean by backflow devices

  • Licence and insurance details on request
  • Price agreed before work
  • Phone answered day and night
  • Richmond Hill & York Region

Where they are needed

  • Lawn irrigation systems, boilers with chemical treatment, fire sprinklers and many commercial buildings need backflow protection. The Town of Richmond Hill, like many Ontario municipalities, runs a cross-connection control program obliging certain properties to install and test backflow devices; check the current requirements for your property.
  • In a typical house, the simplest backflow protection is a vacuum breaker on outdoor taps and an air gap on appliance drains.

Devices

  • The two testable devices you will meet most are the double check valve assembly and the reduced pressure zone assembly. An RPZ is used for higher-hazard connections and must be installed above ground with a drain for its relief valve. The right device depends on the hazard level.
  • Installation needs space for testing and repair, and the device must be accessible to the tester.

Signs you need this

  • You have an in-ground irrigation system
  • You received a letter from the town about backflow
  • Your business has a boiler or chemical feed
  • A device has not been tested this year
  • Water from a hose sprayer has an odd taste

Annual testing

  • A certified tester has to check these assemblies, normally yearly and again after any install or repair, confirming each check holds tight and the relief valve opens at its set differential.
  • Test results are submitted to the municipality. We can test, repair and submit the paperwork. If the device fails, we repair it and retest.

How the job runs

  1. 1

    The hazard level and the required device are confirmed.

  2. 2

    The device is installed with access for testing.

  3. 3

    The device is tested and any failed parts are repaired.

  4. 4

    Results are submitted to the town as required.

Richmond Hill note: most houses here sit on York Region municipal water with fairly hard supply, and many basements have a floor drain tied to the sanitary lateral. Mention both on the phone; it changes what goes on the truck.

Want a second opinion on your own pipes first? Dial (365) 363-1575; the person answering holds the wrench.